Test report · tested November 22, 2026

Memory & StorageDevice under test

VAST Simulations Put Petabyte-SSD Data-Loss Odds at 1 in 11

VAST Data's SC26 simulation puts data-loss odds on a 900 PB petabyte-SSD system at 1 in 11 over ten years with enclosure-level declustered RAID, versus 1 in 62 billion for its own scheme.

Read
4 min
Words
774
Segment
Memory & Storage
Operator
Priya Raman

Spec summary

  1. VAST's 900 PB simulation shows 1-in-11 odds of data loss over 10 years for enclosure-local declustered RAID with petabyte SSDs.
  2. 900 PB from 15 TB drives would draw 5.6 MW; 122 TB drives bring power to roughly 400 kW.
  3. The simulated system used 7,920 122 TB SSDs across 180 enclosures; RAID 5 gave 100% loss odds, double parity 1 in 150.
  4. Metadata replication at three copies yields 1-in-58-million odds, versus 1 in 78 trillion for data drives.
  5. Micron's 245 TB 6600 ION shipped in May; Kioxia, SanDisk, Solidigm and others are pushing toward petabyte-class drives.
VAST says petabyte SSDs will outgrow today’s parallel file system RAID
VAST says petabyte SSDs will outgrow today’s parallel file system RAID — MightyFineBros / pixabay

A VAST Data simulation of a 900 PB all-flash system puts the odds of data loss at 1 in 11 over ten years once petabyte-class SSDs replace today's drives. Glenn Lockwood, the company's principal technical strategist, presented the figures at Supercomputing 2026 in an Exhibitor Forum talk during the HPC System Hardware and Architecture session. He described the model as a "discrete event simulation" (an event-by-event failure model) built on real failure data. VAST sells its own erasure-coding scheme, so its simulation warrants scrutiny.

The core problem is rebuild time. Larger drives take longer to reconstruct after a failure, which widens the window in which a second failure can destroy data. At the same per-drive speed, a 122 TB drive takes twice as long to rebuild as a 60 TB drive. Lockwood acknowledged the standard objection to a 245 TB drive: it is "a big blast radius." Per-drive capacity is potentially outpacing bandwidth growth, and within a generation "the performance of each individual drive does not change."

Why operators will still want petabyte drives

The case rests on power. Storage power scales with bandwidth, not capacity, at roughly 28 W per SSD including infrastructure share, plus 20 W per GB/s of bandwidth. Building 900 PB from 15 TB drives would require more than 63,000 drives, delivering 190 TB/s at 5.6 MW — what Lockwood called "the equivalent of 3,100 or so of Blackwell Ultra GPUs." He added that "real AI applications in our experience have never approached needing anything close to that level of performance" from storage.

Using 122 TB drives, roughly 8,000 of them, cuts aggregate bandwidth to 8 TB/s and power to about 400 kW, less than a tenth. Within that power budget, 15 TB SSDs top out at about 250 PB with no headroom for performance. The freed power can go to compute. The 245 TB class is already arriving, and larger drives are on roadmaps.

What did the simulation measure?

The modeled system held 7,920 SSDs at 122 TB each, in 180 enclosures of 44 drives. The results:

  • RAID 5 single parity: 100% chance of data loss over ten years. "No one uses single parity anymore," Lockwood said.
  • Double parity: 1 in 150, called "state of the art for many open source file systems," with Lustre and BeeGFS named explicitly.
  • Enclosure-local declustered RAID (RAID data, parity and spares spread across extra drives within one box), the approach attributed to DDN EXAScaler and HPE Cray ClusterStor: 1 in 11 with petabyte drives.
  • Global declustering plus extra parity, Lockwood's stated minimum: 1 in 54 million.
  • VAST's own scheme, not detailed: about 1 in 62 billion, three orders of magnitude better.

DDN's DCR, in one published configuration, uses RAID 6 in an 8+2 array for a 24-SSD pool. DDN has previously conceded that larger systems may need more than DCR. HPE's GridRAID declusters parity per enclosure half. Perlmutter at Berkeley Lab's NERSC, Lockwood's former employer, used GridRAID with 8+2+1 per 12-drive object storage target. In every case, protection stops at two failures, and only drives in one box can assist a rebuild.

What are the trade-offs?

Triple parity and global declustering each reduce risk, but global stripes span every drive, so two random failures more often hit the same stripe — a larger fault domain. VAST already publishes quadruple parity. Its "special magic" beyond that is undisclosed.

Metadata is the weakest link. VAST keeps its index on separate fast SSDs as three replicated copies, surviving two failures versus four parity strips for data. With 122 TB drives, data drives sit at 1 in 78 trillion over ten years; metadata sits at 1 in 58 million. Metadata rebuilds start about 12 seconds after failure, versus two minutes for data. VAST's procedure on a dropped drive is to power-cycle it and wait; an hour's delay "wouldn't make a big difference" for data, but 20 minutes on a metadata drive carries "extremely high" risk.

The hardware pipeline is real: Micron ships the 245 TB 6600 ION (30 W maximum), Kioxia's LC9 appears in a Dell 2U server holding 40 drives for 9.8 PB, SanDisk's 256 TB UltraQLC was due in the first half of this year, and Solidigm targets roughly 245 TB later. Roadmaps from SanDisk, SK hynix and Samsung reach petabyte class. The power math supports VAST's argument. The failure data behind it does not get an open comparison, and that gap is where the claims should be tested.

via tomshardware.com (Source)

Filed under

  • petabyte-ssds
  • data-durability
  • raid
  • erasure-coding
  • storage-power-efficiency