CoolIT and Ecolab ship 3MW liquid cooling CDU for AI racks

CoolIT's CHx 3000 CDU, announced by Ecolab, delivers 3MW of cooling for up to 18 racks at 190kW each, with ships starting Q1 2027.

Read
3 min
Words
649
Node
3nm
Operator
Elena Vasquez

Spec summary

  1. The CHx 3000 CDU delivers 3MW of cooling at a 3°C approach temperature difference, CoolIT's highest-capacity unit to date.
  2. One CDU can cool up to 18 racks at 190kW per rack, supporting direct-to-chip cooling for hardware such as Vera Rubin GPUs.
  3. The unit consumes 75kW and includes Ecolab's 3D TRASAR continuous coolant health monitoring.
  4. Units ship beginning Q1 2027.
  5. Ecolab acquired CoolIT from KKR earlier this year and also announced a Siemens partnership this week.
CoolIT & Ecolab launch 3MW CDU
Fig. ACoolIT & Ecolab launch 3MW CDU — WikiImages / pixabay

CoolIT's new CHx 3000 cooling distribution unit delivers 3MW of cooling capacity at a 3°C (37.4°F) approach temperature difference — the company's highest-capacity CDU to date, and a unit pitched directly at AI-scale hardware like Nvidia's Vera Rubin GPUs.

Ecolab announced the liquid-to-liquid unit this week. The CDU is row- and facility-based, with dual heat exchangers that support 45°C (113°F) warm-water operations. In practice, that means the facility loop can run hot enough to cut chiller dependence, which is where the energy savings live for operators wrestling with dense AI deployments.

For practitioners, the sizing math matters more than the headline figure. One CHx 3000 can cool up to 18 racks at 190kW per rack — roughly the density of next-generation GPU systems, not legacy enterprise loads. To put it in perspective, a single unit now covers what would have taken multiple smaller CDUs just a few years ago.

What does it cost in power and what's inside?

The CDU itself consumes 75kW. That's the overhead you're trading for 3MW of cooling capacity — about 2.5 percent of the load it serves, a ratio worth keeping in mind when comparing vendor specs.

Inside the unit sits Ecolab's 3D TRASAR technology, which provides built-in continuous coolant health monitoring. It tracks temperature, differential pressure, pH, conductivity, turbidity, flow rate and glycol concentration in the cooling loop serving the IT equipment. If you've been managing coolant quality with periodic sampling, this moves it to a live signal.

"AI is advancing at an extraordinary pace, and the infrastructure behind it needs to advance just as fast," said Christophe Beck, chairman, president and CEO of Ecolab. "That's exactly what we're enabling today. For too long, cooling hardware, fluid management and digital technology have operated separately. We're bringing them together to help our customers get more computing power, faster, while using less water and energy. And we're just getting started."

When can you get one?

Units ship beginning Q1 2027. That lead time matters for anyone planning facilities around Rubin-class hardware — the cooling design decisions you make now need hardware availability locked in well ahead of rack delivery.

Who's building it?

The CHx 3000 is a multi-vendor effort. Ecolab said it's working with Alfa Laval, drawing on the company's heat exchanger and flow components expertise for the new CDU.

Ecolab's virtual twin technology, developed with Dassault Systèmes, is part of the package too. It links Technology Cooling System (TCS) and facility water system (FWS) models to simulate AI data center performance before you commit to a build.

The same week, Ecolab announced a partnership with Siemens that combines its liquid-cooling and CDU technology with Siemens' power distribution, automation, software and digital twin capabilities. For operators, that pairing points toward integrated procurement of power and cooling rather than stitching the two together on site.

How did Ecolab get here?

Founded in 1923 to sell carpet cleaning products, NYSE-listed Ecolab now provides water treatment and monitoring products and services across industries including food, healthcare, hospitality and manufacturing. Data centers are its newest push.

The company launched a data center-centric version of its 3D TRASAR water monitoring product for liquid cooling in 2025, then launched its own liquid cooling portfolio later that year. It acquired CoolIT from KKR earlier this year — a deal that put a established CDU maker under the same roof as the fluid chemistry and monitoring business.

The CHx 3000 is the first visible product of that combination: CoolIT's thermal hardware plus Ecolab's coolant intelligence in a single SKU, with Alfa Laval components and a simulation layer from Dassault Systèmes attached. Expect more of this converged packaging if Beck's "we're just getting started" line is anything to go by.

via datacenterdynamics.com (Source)

Filed under

  • liquid-cooling
  • cooling-distribution-unit
  • ai-datacenter
  • coolit
  • ecolab
Share this article:

More from Elena Vasquez

Elena Vasquez

Show full bio

Senior reporter covering people, launches and day-to-day practice in hardware layer of artificial intelligence at Die Signal.

675 articles

Same lot · LOT-362E

« Previous article